| B). ACCESSORIES/FEATURES PROVIDED AS STANDARD IN EACH ACB (AR/AT-SERIES) |
|
|
| |
|
|
|
|
|
| 1 |
STANDARD TRIP TYPE: |
True RMS Sensing + Selectivity. |
|
| 2 |
PROTECTIONS: |
|
LSIG |
|
|
| 3 |
AUXILIARY SWITCHES: |
4C (AR Types). |
|
|
| 4 |
TRIP INDICATIONS/SWITCHES: |
The associated LED is lit to indicate which trip function, LTD, STD/INST |
| |
|
|
or PTA ALARM CONTACTS: has operated. Also voltage-free contacts |
| |
|
|
on Trip Device operate simultaneously. PTA Indication & Alarm Switch. |
|
|
| 5 |
PRE-TRIP ALARM: |
|
|
|
| |
|
|
Adj. PTA for Load Control |
|
|
| 6 |
PAD LOCKING: |
|
Provision for Pad Locking the ACB in OPEN position is provided. |
| 7 |
BUILT-IN TESTER: |
|
TEMPOWER ACBs can be tested in the field anytime for precise |
| |
|
|
operation with built-in tester. |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| C). OPTIONAL ACCESSORIES & TRIPPING DEVICES: |
|
|
|
|
| |
|
|
|
|
|
| · |
Trip Indicator Switch |
|
|
|
|
| |
|
|
|
|
|
| · |
Close-Open cycle Counter |
|
|
|
| |
|
|
|
|
|
| · |
Key Interlock |
|
|
|
|
| |
|
|
|
|
|
| · |
Key Interlock System |
|
|
|
| |
|
|
|
|
|
| · |
Mechanical Interlock (between 2 ACBs) |
|
|
|
| |
|
|
|
|
|
| · |
Mechanical Interlock (between 3 ACBs) |
|
|
|
| |
|
|
|
|
|
| · |
Add for Adjustable Earth Fault Protection Relay (w/o 4th CT) for 3Pole ACB… |
|
| |
Add for Adjustable Earth Fault Protection Relay (w/built-in 4th CT) for 4Pole ACB |
|
| |
|
|
|
|
|
| · |
Add for Aux CT for enabling EF Protection |
|
|
|
| |
|
|
|
|
|
| · |
Under-Voltage Trip (Time Delay Type): with remote trip option, Selectable Voltages. |
|
| |
|
|
|
|
|
| · |
Shunt trip |
|
|
|
|
| |
|
|
|
|
|
| · |
Motor Mechanism for Spring Charging |
|
|
|
| |
|
|
|
|
|
| · |
Add for Aux. Switches 7C instead of standard 4C |
|
|
| |
|
|
|
|
|
| · |
Add for Aux. Switches 10C instead of standard 4C |
|
|
| |
|
|
|
|
|
| · |
Spring Charge Indication Switch |
|
|
|
| |
|
|
|
|
|
| · |
Drawout ACBs with cradle |
|
|
|
| |
|
|
|
|
|
| · |
Safety Shutters for Drawout cradle |
|
|
|
| |
|
|
|
|
|
| · |
Closing Operations: Motor charging or solenoid operation |
|
|
| |
|
|
|
|
|
| · |
Closing Latch Release (CLR) for Remote ON for charged ACB(for manual/motorized) |
|
| |
|
|
|
|
|
| · |
Spare OCR for "AT/AR" Series |
|
|
|
| |
|
|
|
|
|
| · |
IP55 Cover (for mounting on switchboard door to provide IP55 deg. of protection |
|
| |
|
|
|
|
|
| · |
Door Flange (Covers the panel cut-out on the switchboard) |
|
|
| |
|
|
|
|
|
| · |
Digital Remote Monitor for ACBs |
|
|
|
| |
|
|
|
|
|
| · |
Communication Interface Unit for AR Series |
|
|
| |
|
|
|
|
|
| · |
Contact Temperature Monitoring Function |
|
|
| |
|
|
|
|
|
| Note: GFT: For 3P ACB use a standard -/5A CT for the Neutral pole. Also please use additional Aux CT for 3P / |
|
| 4P ACB for EF/GF protection. |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| TERASAKI TemPower2 ACBs are based on True R.M.S. Sensing + Selectivity. |
|
|
| Hence they are designed for use as Main Incoming Breaker as well as a Secondary Breaker. |
|
|
| |
|
|
|
|
|
| TERASAKI TemPower2 ACBs are custom designed. |
|
|
|
| Your individual specifications can be incorporated by the factory. For 4-POLE and Drawout ACBs AND |
|
| FURTHER DETAILS, PLEASE CONTACT US. |
|
|
|
|
| |
|
|
|
|
|
| NOTE: |
|
|
|
|
|
| This list is subject to change without notice and goods being in stock. The prices in the list are reference prices and not sale prices. |
|
| Discounts/Multipliers are applicable. The delivery, packing and forwarding charges are extra. |
|
|
| All dispatches are made on buyer’s risk and account. |
|
|
|
|