Emirel V3-12-B Phase Sequence Relay – RST...
PHASE SEQUENCE RELAY – RST (3-Phase)
Model : V3-12-B
Voltage Range: 240 ~ 600V 50/60Hz
Din Rail Mounting
Auto Reset when phase sequence is restored
PHASE SEQUENCE RELAY – RST (3-Phase)
Model : V3-12-B
Voltage Range: 240 ~ 600V 50/60Hz
Din Rail Mounting
Auto Reset when phase sequence is restored
Model : E363 with socket 11P FC
Supply Voltage: 115VAC or 230VAC
Sensing: 3-Phase 415VAC
CT secondary input : 5A or 1A
Reverse Power Adj. : 10% to 100% (load to generator)
Time Delay Setting: 1 to 40 sec adjustable
Power Rating selectable through CT
Power Supply: 230VAC
LED Indicators:
Supply:...
Type: EOCRSS 05/60NU
Supply Voltage : 100VAC - 240V AC/DC
Contacts : 1C
Starting Delay Time Setting Range : 1 to 30 sec
Operating Time Setting Range : 0.5, 1 to 10 sec
Contact Rating : 3A/250VAC
Load Current Setting Range : i. 0.5A to 6.5A
ii....
EOCRSS-05
Supply Voltage : 24 - 240V AC/DC
Contacts : 1A+1B
Starting Delay Time Setting Range : 1 to 30 sec
Operating Time Setting Range : 0.5, 1 to 10 sec
Contact Rating : 3A/250VAC
Load Current Setting Range : i. 0.5A to 6.5A
ii. 5A to 60A
EOCR-SSD
Supply Voltage : 220VAC ± 15%
Starting Delay Time (D-Time) : 1 ~ 30 sec
Trip Time (O – Time) : 0.5, 1~10 sec
Contact Ratings : 2 –SPST, 3A 250VAC
Load Current : 0.5 ~ 6A
10 ~ 60A
Higher currents with external CT
PROTECTIONS:
Protective Item : Ground Fault
Trip Time : O- Time
FEATURES:
MCU based compact design
Ground fault protection with ZCT*
Trip & Run indication LED
Manual / Electrical Reset
FEATURES:
Applicable for Ground Fault protection Devices (EGR)
Detect Zero Phase Current
For EOCR only
1. ZCT-35 , 200A
2. ZCT-80 , 600A
3. ZCT-120 , 800A/1000A
FEATURES:
MCU based , Real time processing / High Precision
Three Integral Current Transformers “Hole Types”
3 TCC (Time –Current Characteristics)- Definite, Inverse and Thermal Inverse: Selectable
Thermal protection / Inverse TCC available up to 32A without...
FEATURES:
MCU based , Real time processing / High Precision
Three Integral Current Transformers “Hole Types”
3 TCC (Time –Current Characteristics)- Definite, Inverse and Thermal Inverse: Selectable
Thermal protection / Inverse TCC available up to 32A without...
Type:EOCR – iFMS-WRDUW (Display Separated)
Mounting: Panel / Din-Rail / Flush Mount
With Over current, Undercurrent, Short circuit Protection, Ammeter and
Communication (RS-485 Modbus
Type: EOCR- i3MZ-WRDUW
(Display built-in)
With – Over current, Undercurrent, Earth Fault, Ammeter and
Communications (RS485 Modbus)